8200-M024-O1 Rev H y 205 Installation & Technical 1 205 WEIGHT INDICATOR INSTALLATION and TECHNICAL MANUAL 82
8200-M024-O1 Rev H y 205 Installation & Technical 6 INSTALLATION Before beginning installation of your Model 205 Weight Indicator, make certain th
8200-M024-O1 Rev H y 205 Installation & Technical 7 CAUTION! Disconnect any external load cell power supply before connecting load cells to the i
8200-M024-O1 Rev H y 205 Installation & Technical 8 INSTALLATION, CONT. Load Cell Cable Shield Wire Connection for RFI Suppression 1. After all t
8200-M024-O1 Rev H y 205 Installation & Technical 9 INSTALLATION, CONT. Serial I/O Cable Installation The 205 indicator may be connected to a prin
8200-M024-O1 Rev H y 205 Installation & Technical 10 INSTALLATION, CONT. Main PCB Figure No. 7
8200-M024-O1 Rev H y 205 Installation & Technical 11 INSTALLATION, CONT. Main PCB Jumpers J1 – BATTERY CHARGE MODE Place jumper J1 in the Full pos
8200-M024-O1 Rev H y 205 Installation & Technical 12 KEYPAD FUNCTIONS The Model 205 is equipped with a 7-key keypad. The keypad is used to enter
8200-M024-O1 Rev H y 205 Installation & Technical 13 KEYPAD FUNCTIONS, CONT. NET/GROSS KEY This key is used to toggle between Net and Gross weight
8200-M024-O1 Rev H y 205 Installation & Technical 14 KEYPAD FUNCTIONS, CONT. ASTERISK, UNITS KEY This combination will enter the Test mode. The Te
8200-M024-O1 Rev H y 205 Installation & Technical 15 ANNUNCIATORS Annunciators are turned on to indicate that the display is in the mode correspon
8200-M024-O1 Rev H y 205 Installation & Technical 2
8200-M024-O1 Rev H y 205 Installation & Technical 16 SETUP AND CALIBRATION Your Model 205 indicator has been thoroughly tested and calibrated befo
8200-M024-O1 Rev H y 205 Installation & Technical 17 SETUP AND CALIBRATION, CONT. Pressing the calibration switch at any prompt will return you to
8200-M024-O1 Rev H y 205 Installation & Technical 18 SETUP AND CALIBRATION, CONT. '0-;> (Weighing Unit 1) Press the TARE/ENTER key to sho
8200-M024-O1 Rev H y 205 Installation & Technical 19 SETUP AND CALIBRATION, CONT. ;9!> (4% Zero Range) Press the TARE/ENTER key to show the cur
8200-M024-O1 Rev H y 205 Installation & Technical 20 SETUP AND CALIBRATION, CONT. `@`3 (`@`3) - Analog to Digital Filtering 3!;> (Digital F
8200-M024-O1 Rev H y 205 Installation & Technical 21 SETUP AND CALIBRATION, CONT. FILTER SETTING RECOMMENDATIONS Non Critical Sample Rate If the s
8200-M024-O1 Rev H y 205 Installation & Technical 22 SETUP AND CALIBRATION, CONT. ! (!) - Calibration With ! (!) displayed, press the TA
8200-M024-O1 Rev H y 205 Installation & Technical 23 SETUP AND CALIBRATION, CONT. Dual-Point with Zero (First Zero) Calibration IMPORTANT! The f
8200-M024-O1 Rev H y 205 Installation & Technical 24 SETUP AND CALIBRATION, CONT. Dual-Point without Zero (False Zero) Calibration IMPORTANT! Th
8200-M024-O1 Rev H y 205 Installation & Technical 25 SETUP AND CALIBRATION, CONT. Single-Point for Zero Only (Only Zero) Calibration IMPORTANT!
8200-M024-O1 Rev H y 205 Installation & Technical ITABLE OF CONTENTS SPECIFICATIONS - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
8200-M024-O1 Rev H y 205 Installation & Technical 26 SETUP AND CALIBRATION, CONT. *-6 (*-6) - Serial Input/Output With *-6 (*-6) displayed, pres
8200-M024-O1 Rev H y 205 Installation & Technical 27 SETUP AND CALIBRATION, CONT. If SMA is selected, the data will be transmitted in the followin
8200-M024-O1 Rev H y 205 Installation & Technical 28 SETUP AND CALIBRATION, CONT. If WI110 is selected, the data will be transmitted in the follow
8200-M024-O1 Rev H y 205 Installation & Technical 29 SETUP AND CALIBRATION, CONT. ;9:> (Threshold Weight) Press the TARE/ENTER key to show the
8200-M024-O1 Rev H y 205 Installation & Technical 30 SETUP AND CALIBRATION, CONT. $9-0; ($9-0;) - Print Tab Settings With $9-0; ($9-0;) displaye
8200-M024-O1 Rev H y 205 Installation & Technical 31 SETUP AND CALIBRATION, CONT. `> (Gross Weight Accumulator Print Location) Press the TA
8200-M024-O1 Rev H y 205 Installation & Technical 32 SETUP AND CALIBRATION, CONT. `*$0 (*$0) - Fine Span Adjustment NOTE! The *$0 and -`
8200-M024-O1 Rev H y 205 Installation & Technical 33 SETUP REVIEW The 205 indicator allows several operational parameters to be reviewed and chang
8200-M024-O1 Rev H y 205 Installation & Technical 34 ACCUMULATORS To view the NET accumulator: 1. Press the ASTERISK/UP ARROW key then the NET/G
8200-M024-O1 Rev H y 205 Installation & Technical 35 BEFORE YOU CALL FOR SERVICE The 205 indicator has been designed to provide you with years of
8200-M024-O1 Rev H y 205 Installation & Technical II FCC COMPLIANCE STATEMENT WARNING! This equipment generates uses and can radiate radio freque
8200-M024-O1 Rev H y 205 Installation & Technical 36 ERROR CODES The 205 indicator is equipped with software that indicates when an error in the o
8200-M024-O1 Rev H y 205 Installation & Technical 37 ERROR CODES, CONT. 99 (Error 1) A program checksum mismatch has been detected. CORRECTIVE
8200-M024-O1 Rev H y 205 Installation & Technical 38 CALIBRATION SEAL INSTALLATION If your Model 205 Weight Indicator is used in a commercial appl
8200-M024-O1 Rev H y 205 Installation & Technical 39 PART IDENTIFICATION (Rear Enclosure Sub Assembly) ITEM NO. QTY. PART NUMBER DESCRIPTION 1 8
8200-M024-O1 Rev H y 205 Installation & Technical 40 PART IDENTIFICATION (Rear Enclosure Sub Assembly)
8200-M024-O1 Rev H y 205 Installation & Technical 41 PART IDENTIFICATION (Front Enclosure Sub Assembly) ITEM NO. QTY. PART NUMBER DESCRIPTION 1
8200-M024-O1 Rev H y 205 Installation & Technical 42 PART IDENTIFICATION (Final Assembly) ITEM NO. QTY. PART NUMBER DESCRIPTION 1 1 593GR986 SERI
8200-M024-O1 Rev H y 205 Installation & Technical 43 APPENDIX A: MODEL 205DC The Model 205DC indicator has been created to change the input power
8200-M024-O1 Rev H y 205 Installation & Technical 1 STATEMENT OF LIMITED WARRANTY WARRANTY TERMS Cardinal Scale Manufacturing Company warrants th
8200-M024-O1 Rev H y 205 Installation & Technical 2 PRODUCT TYPE TERM MATERIAL AND WORKMANSHIP LIGHTNING DAMAGE See note 9 WATER DAMAGE See note
8200-M024-O1 Rev H y 205 Installation & Technical 1 SPECIFICATIONS Power Requirements: 100 to 240 VAC (50/60 Hz) at 0.4A Enclosure Type: Stain
8200-M024-O1 Rev H y 205 Installation & Technical 3 APPLICABLE LIMITATIONS AND REQUIREMENTS 1. This warranty applies only to the original purchas
8200-M024-O1 Rev H y 205 Installation & Technical 4 EXCLUSIONS This warranty does not include replacement of consumable of expendable parts. The
Addendum to the 200, 205, 210 and 215 Installation and Technical Manual TEST MODE This addendum is to inform you of the TEST MODE feature in the 200,
Addendum to the 200, 205, 210 and 215 Installation and Technical Manual This addendum is to inform you of changes to the 200, 205, 210 and 215 Weig
CONTINUOUS DATA OUTPUT FORMATS TOLEDO Beginning with version 2.6.1 of the firmware, the Toledo output has been expanded to provide a selection between
CONTINUOUS DATA OUTPUT FORMATS, CONT. RANGER 5000 FORMAT A Beginning with version 2.6.1 of the firmware, the Ranger 5000 Format A has been added to th
200, 205, 210 and 215 Rev 2.6.1 Addendum 4 CONTINUOUS DATA OUTPUT FORMATS, CONT. GEDGE 1650 FORMAT 4 Beginning with version 2.6.1 of the firmware, the
Addendum to the 200, 205, 210 and 215 Installation and Technical Manual This addendum is to inform you of changes to the 200, 205, 210 and 215 Weig
8200-M024-O1 Rev H y 205 Installation & Technical 1
8200-M024-O1 Rev H y 205 Installation & Technical 2 SPECIFICATIONS, CONT. Standard Features: • Push button tare function • Gross, tare, net conv
8200-M024-O1 Rev H y 205 Installation & Technical 3 EUROPEAN DECLARATION OF CONFORMITY Manufacturer: Cardinal Scale Manufacturing Company PO Box
8200-M024-O1 Rev H y 205 Installation & Technical 4 PRECAUTIONS Static Electricity CAUTION! This device contains static sensitive circuit cards
8200-M024-O1 Rev H y 205 Installation & Technical 5 SITE PREPARATION REQUIREMENTS Electrical Power The 205 indicator has been designed to operate
Comments to this Manuals