Detecto 6437 Operations Instructions Page 4

  • Download
  • Add to my manuals
  • Print
  • Page
    / 20
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 3
UNPACKING INSTRUCTIONS
x Remove scale from carton by lifting up with equal force from column and platform base.
x Check for any damage incurred in shipping. If scale has been damaged, place a claim with
the carrier. Use the original carton and shipping material to return the scale.
x Remove all plastic wrapping, foam fillers and cardboard material from the scale.
x Carton contents:
1) Column
NOTE! If column bracket is bent,
straighten before assembling.
2) Indicator
3) Platform base
4) Screws and lock washers
5) Hand post - optional
6) Height measuring rod - optional
7) Wheels - optional
ASSEMBLY INSTRUCTIONS
Refer to Figures No. 1, 2, 3, and 4, then follow the instructions for scale assembly.
1. Carefully remove load cell and draft rod assembly from column.
IMPORTANT! Handle load cell assembly with care! Do not drop, bend or twist.
2. Slip column over column bracket on platform base. Screw column to column brackets
(two 1/4 truss head screws in front of column and four in the back). See Figure No. 1.
3. Referring to Figure No. 2, remove both #10-32 Truss Head Screws and lock washers
securing the indicator bracket to the column.
4. Lower load cell and draft rod assembly into column. Draft Rod must pass through
opening in column bracket. Referring to Figure No 1, make sure open end of lower draft
rod hook is facing forward toward platform.
5. Next, referring to Figure No. 3, fasten top hook bolt of load cell assembly (C) to column.
Make sure the load cell assembly does not touch the sides of column.
6. Slide grommet away from load cell assembly and slide into slot on column. NOTE! The
slot should be on back (wide side) of column.
7. Pull excess load cell cable in column leaving enough slack in cable so as not to have
any side pull on load cell.
8. Place digital indicator bracket on column and attach with 2 (#10-32) truss head screws
and lock washers removed in step 3. See Figure No. 2.
9. Using a desk or table, lay down scale with column horizontal to floor. Raise draft rod
keeping out of lever's way. Push lever. When lever is in position, hook draft rod around
pivot. See Figure No. 4.
10. Attach indicator to indicator bracket on column, then connect load cell cable to back of
indicator. Refer to the 758C Owner’s Manual, 8555-M210-O1 for additional information.
11. Scale is now ready for operation.
0033-M114-O1 Rev F x Model 6437 Series